CASE REPORT
The use of Triple Stapling Technique with Automatic Stapling Device for Laparoscopic Sigmoidectomy -A Case Report-
Kazuya Kato, Minoru Matsuda, Yasuhiro Yamamoto, Toshihide Arai, Kazuhiko Onodera, Shinichi Kasai, Michio Mito, Tastuo Kobayashi*, Takashige Saito**
Second Department of Surgery, Asahikawa Medical College
*Kobayashi Hospital
**Higashiasahikawa Hospital
The feasibility of performing a sigmoidectomy with laparoscopic technique using a triple stapling technique (TST) was demonstrated in the current study. A 55-year-old man had a sigmoidal colon polyp, which was pathologically diagnosed as group 4. Sigmoidectomy was performed with a laparoscopic technique using an endopath lenear cutter 60®. The laparoscopic technique for anastomosing the procedure to be performed completely within the abdominal cavity using a curved detactable head (CDH)®. The procedure appears to be safe, and there is no compromise in the standard sigmoidectomy.
Key words
laparoscopic sigmoidectomy, triple stapling technique, automatic stapling device
Jpn J Gastroenterol Surg 27: 820-823, 1994
Reprint requests
Kazuya Kato Second Department of Surgery, Asahikawa Medical College
4-5 Nishi-Kagura, Asahikawa, 078 JAPAN
Accepted
November 1, 1993
|
To read the PDF file you will need Abobe Reader installed on your computer. |
|